Liquid Channel Troubleshooting guide

No LEDs illuminated
• Is the POWER switched on?
• Is the correct mains voltage being used for your unit? If not, the fuse may blow, requiring the correct fuse to be refitted. (Click here to find the fuse rating for your unit.)

No output when using the MIC INPUT
• Is the POWER switched on?
• Is the MIC LED next to the SELECT switch illuminated?
• Is the LEVEL set correctly?
• For microphones that require phantom power, is the +48V switch engaged? (If you are unsure whether your microphone requires phantom power, check the user guide for your microphone.)

No output when using the LINE INPUT
• Is the POWER switched on?
• Is the LINE LED next to the SELECT switch illuminated?
• Is the LEVEL set correctly?

Output sounds DISTORTED
• Is the Input gain too high?
• Is the Compressor switched in, and the Makeup Gain set too high?
• Is the EQ switched in, and the gain set too high?
• Is the HARMONICS dial turned up?

The COMPRESSOR is not working
• Is the COMP IN switch engaged?
• Is the LEVEL set correctly? If set too low, the signal level may not be high enough to activate the compressor.
• Are the COMPRESSION controls set correctly? If set too low, the input level may not reach the threshold at which compression starts. (See manual for more info.)
• Is the LISTEN switch illuminated? This will result in monitoring of the compressor’s sidechain. (See manual for more info.)
• Is the BYPASS switch in the ‘COMP & EQ BYPASS’ section engaged? This deactivates all EQ and Dynamics.

The EQ section is not working
• Is the EQ IN switch engaged?
• Is the appropriate band’s frequency dial set to act on a frequency that is present in the signal?.
• Is the BYPASS switch in the ‘COMP & EQ BYPASS’ section engaged? This deactivates all EQ and Dynamics.

No word clock lock
• Is your external word clock source transmitting word clock?
• Is the sample frequency set to match that of the word clock-transmitting device? • Is an external word clock cable needed and, if so, is it connected? (See clocking regulations in the GENERIC SETUP.)

No output from the digital output
• Is the sample frequency set correctly?
• Does the receiving device accept AES format?
• Is the receiving device set to receive the correct resolution (24-bit)?
• Is the receiving device set to external sync? (See DIGITAL in GENERIC SETUP.)
• At 192kHz, is the receiving device a one- or two-wire system?

Related Articles

article ISA220 Troubleshooting guide
No LEDs illuminated • Is the POWER switched on? • Is the correct mains voltage being used for your unit? If not, the fuse may blow, requiring the correct fuse to be refitted. (Click here to find...

2009-06-26    Views: 3693   
article Guide to Setting up your Studio Part 2
Back To Part 1 | Continue To Part 3 Impedance Issues Some users seem concerned about whether the impedance differences between various inputs and outputs will cause any problems with their...

2005-08-04    Views: 30308   
article Guide to Setting up your Studio Part 3
Back To Part 2 Fig. 8: Table of fuses required for Focusrite units Focusrite deviceFuse 230/220V ACFuse 115/100V AC Red 1 T250mA anti-surge (Time lag) T500mA anti-surge (Time...

2005-08-04    Views: 19869   
article Guide to Setting up your Studio Part 1
Continue To Part 2This article is a tutorial-style guide to setting up your system correctly, and eliminating any problems to get the best results from your studio. The two most popular home...

2005-08-03    Views: 54359   
article Liquid Saffire 56 Troubleshooting Guide
Before consulting this troubleshooting guide, please ensure that you have the latest software from here I am having connection or performance problems - If you are on an XP PC optimise your XP...

2009-09-25    Views: 15562   


.: Powered by Lore 1.6.3

Copyright 2008 Focusrite Audio Engineering Ltd. All Rights Reserved.