Main Index .: Liquid Reihe .: The Liquid Channel .: What steps do I need to take to link two Liquid Channels?

What steps do I need to take to link two Liquid Channels?

To link two Liquid Channels follow these steps:

1) Connect the 'digital link bus' out of the LC you wish to use as master to the 'digital link bus' in of the slave LC.

2) Connect the 'digital link bus' out of the slave LC to the 'digital link bus' in of the master LC.

3) Set the 'Digital Link Bus (Gain Linkage)' to 2 machines on both LCs. To do this press the setup button and press the Data knob until you see the 'Digital Link Bus (Gain Linkage)' menu (this is the third menu). Rotate the Data knob to scroll through the settings (until it says '2 machines') and press it once again to go to the next menu and save your settings.

4) Set the Gain Linkage option to 'machine 1 (master)' on the master LC and to 'machine 2 (slave)' on the slave LC. This is the fourth menu, accessed as in step 3), and the options are selected in the same way. The slave machine will bring up an extra menu - 'Slave controls to master'. For most of the time you will want to select 'Yes' but there may be times when you wish to control them separately.

5) Select the inputs and outputs. For the case when you have an analogue in to each LC and will be using the AES out of the Master. In the 'AES Linking' menu select 'Link AES - right: from slave' on the master LC and 'Link to master AES - right: output' on the slave LC. It is possible to connect a stereo AES signal to the master unit and use both LCs to process the left and right signals respectively and then use a single AES out connection from the master LC. To do this select 'Link AES - right: to and from slave' on the Master LC and select 'Link to master AES - right: in and out' on the slave LC.

6) If you are using the Liquid Control software then in the last setup menu set the USB ID of the master LC to 1 and the USB ID of the slave LC to 2.

Related Articles

article How does the compressor link function work on the Liquid Channel?
With a standard analogue compressor, when link is switched in, a diode circuit ensures that whichever channel requires the most gain reduction controls the action of both compressors. This way the...

2005-08-08    Views: 2572   
article Can I use dynamic link with different ISA models? ISA linking explained.
It is possible to use the dynamic link with any combination of ISA 220, ISA 430 MkI and ISA 430 MkII for stereo dynamics processing. Simply connect a TRS jack cable between the dynamic link...

2005-08-10    Views: 2362   
article Ist mein ´DEVICE LINK´- Kabel korrekt gelötet?
Die erste Charge des ´iTack´ wurde mit einer falschen Bebilderung in der gedruckten Kurzanleitung ausgeliefert und zeigt die Biegung des ´Device Link´-Kabels auf der rechten Seite. Wenn Sie die...

2012-09-26    Views: 247   
article Digital Card Jumper Positions - Disabling Channels 5-8
Four jumpers on the digital card can be made to disable channels 5-8 on the AES Output. This is so that a standard 25-pin to 25-pin Pro ToolsTM cable can be used to record channels 1-4 at 192kHz....

2007-10-15    Views: 1788   
article Noise is present on all four channels of my 428. Is there a fault?
If you have a digital card in your unit then check both analogue and digital outputs for noise. If you can hear the noise on all the analogue outputs as well as the digital outputs check that...

2005-08-10    Views: 2051   