Main Index .: ISA Reihe .: ISA 428 Pre Pack .: The 'lock' LED does not light when syncing my ISA 428 to 256X super clock from Pro Tools. Is something wrong?

The 'lock' LED does not light when syncing my ISA 428 to 256X super clock from Pro Tools. Is something wrong?

When syncing to superclock the 'lock' LED does not actually light and should not be used as an indicator of lock. If you can get a clean digital audio signal out of the 428 and into Pro Tools when set to sync to superclock then you know it is locked. If you get digital noise or nothing at all then check that the sample frequency and bit depth settings are the same on both the 428 and in Pro Tools and set the clock source in Pro Tools to internal/superclock.

Related Articles

article Getting rid of clicks and pops when syncing VoiceMaster pro to an external device.
Firstly ensure the sample frequency is set to the same throughout your system. Also ensure that the clock source on the master clock device is set to 'internal'. If you still hear clicks and...

2005-08-04    Views: 2556   
article I have my ISA card synced internally but the receiving device looses sync resulting in the signal cutting out/digital distortion. What is wrong?
Check that the receiving device is set to sync to the input to which the 428 is connected and the sample frequency and bit depth settings are the same for both the receiving device and on the ISA...

2005-08-10    Views: 2608   
article Using the Octopre in a word clock chain.
It is important to remember that in a digital system all of the units need to be synchronised, thus the need for a common word clock signal feeding all of them. Word clock signal is carried on 75...

2005-08-03    Views: 2282   
article LED not working when push button engaged - what to check.
If a button does not light up when pushed in then it may be that the LED has come out of its socket. You can check this by removing the plastic lens cap (simply pull off) and making sure that...

2005-09-21    Views: 2600   
article Kann ich alle Eingänge bzw. Ausgänge verwenden, wenn ich den Dual Unit Modus mit Pro Tools 9 bzw. 10 benutze?
Die standard Version von Pro Tools 9 und 10, bieten einen Maximum aus 32 simultane Eingänge und Ausgänge. Aus diesem Grund, sollte die Anzahl Ihrer Eingänge bzw. Ausgänge die 32 überschreiten,...